- Formula
- Convert displacement/velocity/acceleration, dB ↔ linear, via ω = 2πf
- Output
- dB or SI unit (depends on selected output), per band
- Bands
- Follows the input spectrum
- Standard / Source
- General acoustics (no standard cited)
- Access
- Toolbar block
What it does
Converts a row of vibration levels between displacement, velocity and acceleration, and between dB and linear representation, at each band — e.g. turning a measured acceleration spectrum in dB into linear displacement for use elsewhere. Conversion between quantities uses ω = 2πf, so it is frequency-dependent even though the dB↔linear step alone is not.
Equation
dB → linear: , with reference values 10⁻¹² m (displacement), 10⁻⁹ m/s (velocity), 10⁻⁶ m/s² (acceleration).
Between quantities, via displacement: , then back out to the target quantity, where ω = 2πf.
Inputs
| Input | Meaning | Unit | Example |
|---|---|---|---|
| Source | vibration levels (a spectrum row) | — | see below |
| Input quantity | quantity/representation of the source row (select) | — | Acceleration (dB re 10⁻⁶ m/s²) |
| Output quantity | quantity/representation to convert to (select) | — | Displacement (dB re 10⁻¹² m) |
Worked example
Acceleration in dB re 10⁻⁶ m/s² → Displacement in dB re 10⁻¹² m:
| Band (Hz) | 16 | 31.5 | 63 |
|---|---|---|---|
| Accel in (dB) | 70 | 75 | 80 |
| Disp out (dB) | 109.9 | 103.1 | 96.1 |
Source
Standard vibration-quantity and dB-reference conversions (reference values per ISO 8041 / common practice for building vibration). No specific published standard is cited in the software for the conversion logic itself.