- Formula
- d = Kr·g·1000 / (2π·f0)²
- Output
- mm, same value in every band
- Bands
- 31.5 Hz – 8 kHz (same value in every band)
- Standard / Source
- General acoustics (no standard cited)
- Access
- Toolbar block
What it does
Gives the static deflection an anti-vibration isolator (spring or elastomeric mount) needs in order to achieve a target resonant (natural) frequency — the inverse of Resonant Frequency from Static Deflection, used when selecting an isolator to a specified isolation performance.
Equation
where Kr is a stiffness-ratio constant (1.4 for rubber/elastomeric bearings, 1.0 for metal springs).
Inputs
| Input | Meaning | Unit | Example |
|---|---|---|---|
| f0 | target resonant frequency | Hz | 5.898 |
| Kr | bearing type (select: rubber/elastomeric = 1.4, metal springs = 1.0) | — | Rubber/elastomeric bearings |
| g | gravitational acceleration | m/s² | 9.81 |
Worked example
f0 = 5.898 Hz, Kr = 1.4 (rubber/elastomeric), g = 9.81 m/s²:
Source
Standard isolator static-deflection/resonant-frequency relation. No specific published standard is cited in the software.