- Formula
- Ltotal = Lw + 10·log₁₀[(Q/4πr²) + (4/Rc)]
- Output
- dB — total SPL per band
- Bands
- Follows the Lw spectrum
- Standard / Source
- General acoustics (no standard cited)
- Access
- Toolbar block
What it does
Gives the total sound pressure level at a receiver inside a room, combining the direct-field contribution (falling off with distance and directivity) with the reverberant-field contribution (set by the room constant) — the standard indoor near/far-field SPL model. It works band by band on a sound power spectrum (since v0.6.1; earlier builds took a single Lw and wrote the same value in every band). Ribbon: Buildings → SPL in Room (Direct + Reverberant).
Equation
Inputs
| Input | Meaning | Unit | Example |
|---|---|---|---|
| Lw | sound power level of the source (a spectrum row) | dB | 90 |
| Q | directivity factor (Spherical=1, Hemispherical=2, Quarter=4, Eighth=8) | — | Spherical |
| r | distance from source to receiver | m | 5 |
| Rc | room constant | m² | 100 |
Worked example
In a band where Lw = 90 dB, with Q = 1 (spherical), r = 5 m, Rc = 100 m²:
direct = 1/(4π·5²) = 0.00318; reverberant = 4/100 = 0.04
The same −13.6 dB offset is applied to every band of the Lw row — e.g. Lw = 85 / 90 / 87 dB at 63 / 250 / 500 Hz gives 71.4 / 76.4 / 73.4 dB.
Source
Standard direct-plus-reverberant indoor SPL model (see also Reverberant SPL, Room Constant). No specific published standard is cited in the software.