- Formula
- fs = 2000·√(T60 / V)
- Output
- Hz (single value)
- Bands
- Scalar (not a spectrum)
- Standard / Source
- General acoustics (no standard cited)
- Access
- Toolbar block
What it does
Gives the Schroeder (statistical modal) frequency of a room — the cut-off above which a room's response can be treated statistically rather than as individual resonant modes. Used alongside Room Mode Frequency to judge whether low-frequency modal behaviour is likely to be audible in a given space. Ribbon: Buildings → Room Acoustics → Schroeder frequency.
Equation
Inputs
| Input | Meaning | Unit | Example |
|---|---|---|---|
| T60 | reverberation time | s | 0.8 |
| V | room volume | m³ | 200 |
Worked example
T60 = 0.8 s, V = 200 m³:
Source
The Schroeder cut-off frequency relation, a standard room-acoustics concept. No specific published standard is cited in the software.