- Formula
- A = 0.161 · V / T₆₀
- Output
- m² — absorption per band
- Bands
- Follows the RT spectrum
- Standard / Source
- General acoustics (no standard cited)
- Access
- Toolbar block
What it does
The inverse of the Sabine equation: given a target (or measured) reverberation time and the room volume, it returns the total absorption required in each band. Useful for working out how much absorptive treatment a room needs to hit an RT target. Ribbon: Buildings → Reverberation → Sabines from RT (named “Sabine Absorption” before v0.8.0).
Equation
Inputs
| Input | Meaning | Unit | Example |
|---|---|---|---|
| T₆₀ | target reverberation time (a spectrum row) | s | 0.8 |
| V | room volume | m³ | 200 |
Worked example
At a band where the target T₆₀ = 0.8 s, with V = 200 m³:
The calculation runs per band across the RT row; a band whose T₆₀ is blank or zero is left blank.
Source
Inverse Sabine relation. No specific published standard is cited in the software.