Skip to content
ContentsFormula ReferenceUser guide
Formula Reference

RT from Sabines — Eyring Reverberation Time

Formula
T₆₀ = 0.161·V / (−S·ln(1 − A/S))
Output
s — reverberation time per band
Bands
Follows the absorption spectrum
Standard / Source
General acoustics (no standard cited)
Access
Toolbar block

What it does

Gives the reverberation time using the Eyring equation, which is more accurate than Sabine in fairly dead rooms (average absorption coefficient above ~0.2). It needs the room's total surface area S as well as the absorption and volume. Ribbon: Buildings → Reverberation → RT from Sabines, with Method = Eyring (the S input appears only for this method). RT from Alpha offers the same Eyring option starting from absorption coefficients.

Equation

T60=0.161 V−S ln⁡ ⁣(1−AS)T_{60} = \frac{0.161\,V}{-S\,\ln\!\left(1 - \dfrac{A}{S}\right)}

As A approaches S (a fully absorbing room) T₆₀ tends to zero (A ≥ S gives 0). A band whose A is blank, zero or negative is left blank.

Inputs

InputMeaningUnitExample
MethodSabine or EyringselectEyring
Atotal absorption (a spectrum row)m²see below
Vroom volumem³200
Stotal surface aream²300

Worked example

V = 200 m³, S = 300 m², same absorption spectrum as the Sabine example:

Band (Hz)31.5631252505001000200040008000
T₆₀ (s)1.5561.5561.4091.2341.0951.0190.9520.8920.865

Slightly shorter than Sabine, as expected for these absorption levels.

Source

The Eyring reverberation equation. No specific published standard is cited in the software.