- Formula
- T₆₀ = 0.161·V / (−S·ln(1 − A/S))
- Output
- s — reverberation time per band
- Bands
- Follows the absorption spectrum
- Standard / Source
- General acoustics (no standard cited)
- Access
- Toolbar block
What it does
Gives the reverberation time using the Eyring equation, which is more accurate than Sabine in fairly dead rooms (average absorption coefficient above ~0.2). It needs the room's total surface area S as well as the absorption and volume. Ribbon: Buildings → Reverberation → RT from Sabines, with Method = Eyring (the S input appears only for this method). RT from Alpha offers the same Eyring option starting from absorption coefficients.
Equation
As A approaches S (a fully absorbing room) T₆₀ tends to zero (A ≥ S gives 0). A band whose A is blank, zero or negative is left blank.
Inputs
| Input | Meaning | Unit | Example |
|---|---|---|---|
| Method | Sabine or Eyring | select | Eyring |
| A | total absorption (a spectrum row) | m² | see below |
| V | room volume | m³ | 200 |
| S | total surface area | m² | 300 |
Worked example
V = 200 m³, S = 300 m², same absorption spectrum as the Sabine example:
| Band (Hz) | 31.5 | 63 | 125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 |
|---|---|---|---|---|---|---|---|---|---|
| T₆₀ (s) | 1.556 | 1.556 | 1.409 | 1.234 | 1.095 | 1.019 | 0.952 | 0.892 | 0.865 |
Slightly shorter than Sabine, as expected for these absorption levels.
Source
The Eyring reverberation equation. No specific published standard is cited in the software.