- Formula
- Rc = A / (1 − A/S) = S·α_avg / (1 − α_avg)
- Output
- m² — room constant per band
- Bands
- Follows the absorption spectrum
- Standard / Source
- SRL — Noise Control in Building Services
- Access
- Toolbar block
What it does
Gives the room constant Rc — a measure of a room's total absorptive capacity relative to its size, used as the reverberant-field term in calcs such as SPL in Room and Reverberant SPL. A larger Rc means a more absorptive (less reverberant) room. Ribbon: Buildings → Reverberation → Room Constant.
Equation
where A is the per-band equivalent absorption area (m²) and S is the total room surface area (m²). If A ≥ S (a fully absorptive room) Rc is returned as infinite.
Inputs
| Input | Meaning | Unit | Example |
|---|---|---|---|
| S | total room surface area | m² | 120 |
| A | absorption area (a spectrum row) | m² | see below |
Worked example
S = 120 m² with the absorption spectrum below:
| Band (Hz) | 31.5 | 63 | 125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 |
|---|---|---|---|---|---|---|---|---|---|
| A (m²) | 10 | 10 | 12 | 14 | 18 | 20 | 20 | 18 | 16 |
| Rc (m²) | 10.91 | 10.91 | 13.33 | 15.85 | 21.18 | 24.00 | 24.00 | 21.18 | 18.46 |
(e.g. at 500 Hz: 18/(1 − 18/120) = 21.18 m².)
Source
SRL, *Noise Control in Building Services* — the Sabine-based room constant relation.