- Formula
- f0 = (1/2π)·√(Kr·g/d)
- Output
- Hz, same value in every band
- Bands
- 31.5 Hz – 8 kHz (same value in every band)
- Standard / Source
- General acoustics (no standard cited)
- Access
- Toolbar block
What it does
Gives the resonant (natural) frequency of an anti-vibration isolator from its known static deflection — the inverse of Static Deflection from Resonant Frequency, used to check the isolation performance of a mount that has already been selected or measured.
Equation
where d is in metres and Kr is a stiffness-ratio constant (1.4 for rubber/elastomeric bearings, 1.0 for metal springs).
Inputs
| Input | Meaning | Unit | Example |
|---|---|---|---|
| d | static deflection | mm | 10 |
| Kr | bearing type (select: rubber/elastomeric = 1.4, metal springs = 1.0) | — | Rubber/elastomeric bearings |
| g | gravitational acceleration | m/s² | 9.81 |
Worked example
d = 10 mm, Kr = 1.4 (rubber/elastomeric), g = 9.81 m/s²:
Source
Standard isolator static-deflection/resonant-frequency relation. No specific published standard is cited in the software.