- Formula
- Lw = Lp + 10·log₁₀(S) − 6
- Output
- dB — sound power level (Lw) per band
- Bands
- Follows the input spectrum
- Standard / Source
- SRL — Noise Control in Building Services
- Access
- Toolbar block
What it does
Converts the reverberant sound pressure level inside a plantroom into the sound power level radiated out through a louvre of area S — the first step in predicting plantroom break-out noise at neighbouring properties.
Equation
where S is the louvre's open area (width × height).
Inputs
| Input | Meaning | Unit | Example |
|---|---|---|---|
| Lp | reverberant SPL in the plantroom (a spectrum row) | dB | see below |
| Width | louvre width | m | 1 |
| Height | louvre height | m | 1 |
Worked example
Louvre 1 × 1 m (S = 1 m², so the offset is 10·log₁₀(1) − 6 = −6 dB), with plantroom Lₚ as shown:
| Band (Hz) | 63 | 125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 |
|---|---|---|---|---|---|---|---|---|
| Lp in (dB) | 90 | 92 | 88 | 85 | 82 | 80 | 78 | 75 |
| Lw out (dB) | 84 | 86 | 82 | 79 | 76 | 74 | 72 | 69 |
Source
SRL, Noise Control in Building Services.