Skip to content
ContentsFormula ReferenceUser guide
Formula Reference

Parallelipiped Area Propagation

Formula
Lp = Lw − 10·log₁₀(S/S₀); S = 4[(0.5A+r)(0.5B+r) + (0.5B+r)(C+r) + (C+r)(0.5A+r)]
Output
dB — attenuation correction, same value in every band
Bands
31.5 Hz – 8 kHz (same value in every band)
Standard / Source
General acoustics (no standard cited)
Access
Toolbar block

What it does

Estimates propagation loss from a rectangular plant item treated as a parallelipiped (box) source — the surface area of an imaginary box drawn at distance r around the source, used the same way as Conformal Area Propagation but with a box rather than a rounded-corner envelope.

Equation

Lp=Lw−10 log⁡10(S/S0)L_p = L_w - 10\,\log_{10}(S/S_0)

where

S=4[(0.5A+r)(0.5B+r)+(0.5B+r)(C+r)+(C+r)(0.5A+r)]S = 4\left[(0.5A+r)(0.5B+r) + (0.5B+r)(C+r) + (C+r)(0.5A+r)\right]

and S₀ = 1 m².

Inputs

InputMeaningUnitExample
Asource lengthm3.6
Bsource widthm2.5
Csource heightm1.7
rdistance of propagationm10

Worked example

A = 3.6 m, B = 2.5 m, C = 1.7 m, r = 10 m:

0.5A+r = 11.8, 0.5B+r = 11.25, C+r = 11.7 → S = 4(132.75 + 131.63 + 138.06) = 1609.7 m²

Correction = −10·log₁₀(1609.7) = −32.1 dB, applied equally to every band.

Source

General box-surface propagation relation for plant enclosures. No specific published standard is cited in the software.

Register interest

Tell us a little about you and we'll be in touch when Timbral is ready.