Formula
NR curve levels L = a + b·N
Output
dB — fills a row with an NR curve
Bands
1/1-octave, 31.5 Hz – 8 kHz
Standard / Source
ISO 1996-1 / BS 8233:2014
Access
Curve fill

What it does

Fills the selected row with the octave-band levels of a chosen NR curve — handy as an overlay to compare a spectrum against, or as a target. The curve number sits in a yellow input cell, so you can change it (e.g. NR 35 → NR 45) and the row recomputes live. It writes a label such as “NR 40” in the first column.

ℹ️ Defined at the nine octave-band (1/1) centres, 31.5 Hz – 8 kHz. It can be filled on any sheet: on a one-third-octave sheet only those nine centre bands are filled and the other bands are left blank. Default curve: NR 40.

Worked example — NR 40

Band (Hz)31.5631252505001000200040008000
Level (dB)82.66756.849.243.44037.134.933.2

(By definition an NR curve reads exactly its own number at 1 kHz.)

Source

ISO 1996-1 / BS 8233:2014, Annex B — NR curve constants. See also the NR (Noise Rating) entry, which rates a spectrum against these curves.