- Formula
- R = 20·log₁₀(f·m) − C (C = 42 normal, 48 diffuse)
- Output
- dB (negative = attenuation)
- Bands
- 1/1-octave 31.5 Hz – 8 kHz; 1/3-octave 25 Hz – 10 kHz (model valid 100 Hz – 3.15 kHz)
- Standard / Source
- General acoustics (no standard cited)
- Access
- Toolbar block
What it does
Estimates the sound reduction index of a simple single-leaf partition from its surface mass, using the mass law: heavier partitions and higher frequencies give more insulation, rising ~6 dB per doubling of mass or frequency. Ribbon: Buildings → Sound Insulation → Mass Law.
Equation
where m is the surface mass (kg/m²) and C is 42 for normal-incidence or 48 for diffuse (random-incidence) sound. The result is written negative (an attenuation). Diffuse is exactly 6 dB less than normal-incidence.
Inputs
| Input | Meaning | Unit | Example |
|---|---|---|---|
| m | surface mass per unit area | kg/m² | 25 |
| Incidence | normal or diffuse | select | diffuse |
Worked example
m = 25 kg/m², diffuse (C = 48):
| Band (Hz) | 31.5 | 63 | 125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 |
|---|---|---|---|---|---|---|---|---|---|
| R (dB) | −9.93 | −15.95 | −21.90 | −27.92 | −33.94 | −39.96 | −45.98 | −52.00 | −58.02 |
(e.g. at 1 kHz: 20·log₁₀(1000×25) − 48 = 87.96 − 48 = 39.96, written −39.96 dB.)
ℹ️ The mass law is an idealisation — it ignores stiffness, the coincidence dip and damping, so real partitions depart from it, especially at high frequency. Bands outside the model's usual 100 Hz – 3.15 kHz range (on a 1/1-octave sheet: 31.5, 63 Hz, 4 and 8 kHz) are still filled, but carry a tooltip marking the value as an extrapolation.
Source
The idealised mass law. The 42 / 48 dB constants are not attributed to a specific published standard in the software.