ISO 9613-2 Ground Attenuation

Formula
Agr = −10·lg[1 + (10^(−A′gr/10) − 1)·Kgeo], A′gr = AS + AR + Am (ISO 9613-2:2024 7.3.1, Table 3)
Output
dB (negative = attenuation; positive = ground gain)
Bands
63 Hz – 8 kHz (Table 3 has no 31.5 Hz row)
Standard / Source
ISO 9613-2:2024
Access
Toolbar block

What it does

Calculates the ground attenuation Agr between a source and a receiver over flat (or constant-slope) ground, downwind, by the general method of ISO 9613-2:2024 clause 7.3.1. The ground is split into a source region, a middle region and a receiver region, each with its own ground factor G (0 = hard, 1 = porous).

Equation

Agr=−10log⁡10[1+(10−Agr′/10−1)Kgeo],Agr′=AS+AR+AmA_{gr} = -10\log_{10}\left[1 + \left(10^{-A'_{gr}/10} - 1\right)K_{geo}\right],\qquad A'_{gr} = A_S + A_R + A_m
Kgeo=dp2+(hS−hR)2dp2+(hS+hR)2K_{geo} = \frac{d_p^2 + (h_S - h_R)^2}{d_p^2 + (h_S + h_R)^2}
  • AS, AR — the source and receiver region terms from Table 3, per band: −1.5 at 63 Hz; −1.5 + G·a′(h), b′(h), c′(h), d′(h) at 125, 250, 500, 1000 Hz; −1.5(1 − G) at 2–8 kHz, with G and h the region's ground factor and height.
  • Am — the middle region term: −3q at 63 Hz, −3q(1 − Gm) above, with q = 0 when dp ≤ 30(hS + hR), else q = 1 − 30(hS + hR)/dp.
  • The height functions (Table 3):
a′(h)=1.5+3.0 e−0.12(h−5)2(1−e−dp/50)+5.7 e−0.09h2(1−e−2.8×10−6dp2)a'(h) = 1.5 + 3.0\,e^{-0.12(h-5)^2}\left(1 - e^{-d_p/50}\right) + 5.7\,e^{-0.09h^2}\left(1 - e^{-2.8\times10^{-6}d_p^2}\right)
b′(h)=1.5+8.6 e−0.09h2(1−e−dp/50),c′(h)=1.5+14.0 e−0.46h2(1−e−dp/50),d′(h)=1.5+5.0 e−0.9h2(1−e−dp/50)b'(h) = 1.5 + 8.6\,e^{-0.09h^2}\left(1 - e^{-d_p/50}\right),\quad c'(h) = 1.5 + 14.0\,e^{-0.46h^2}\left(1 - e^{-d_p/50}\right),\quad d'(h) = 1.5 + 5.0\,e^{-0.9h^2}\left(1 - e^{-d_p/50}\right)

ℹ️ The source region extends 30·hS from the source and the receiver region 30·hR back from the receiver (each at most dp); the middle region is the rest. G for each region is an input: averaging a mixed region (Formula 10) is up to you. Timbral writes the result as −Agr, so a ground gain (negative Agr) shows positive. Bands 63 Hz – 8 kHz only.

Inputs

InputMeaningUnitExample
hSsource heightm1.5
hRreceiver heightm4
dpsource–receiver distance projected onto the ground plane (must be greater than 0)m200
GS, Gm, GRground factor of the source, middle and receiver regions (0–1; blank reads as 0, hard)—0, 0.5, 1

Worked example

hS = 1.5 m, hR = 4 m, dp = 200 m, GS = 0, Gm = 0.5, GR = 1. Then q = 1 − 30 × 5.5 / 200 = 0.175 and Kgeo = 0.9994.

Band (Hz)631252505001000200040008000
AS (dB)−1.50−1.50−1.50−1.50−1.50−1.50−1.50−1.50
AR (dB)−1.502.762.000.010.000.000.000.00
Am (dB)−0.53−0.26−0.26−0.26−0.26−0.26−0.26−0.26
Agr (dB)−3.520.990.24−1.75−1.76−1.76−1.76−1.76
Result, −Agr (dB)3.5−1.0−0.21.81.81.81.81.8

(e.g. at 125 Hz: AR = −1.5 + 1 × a′(4) = −1.5 + 4.26 = 2.76 dB; A′gr = −1.50 + 2.76 − 0.26 = 0.99 dB.)

Source

ISO 9613-2:2024 — clause 7.3.1 (general method), Formulae (11)–(13) and Table 3. Bands 63–8000 Hz.