- Formula
- Aatm = αatm·d/1000, αatm (dB/km) from ISO 9613-1 at the exact band centre frequency
- Output
- dB (negative = attenuation)
- Bands
- 63 Hz – 8 kHz
- Standard / Source
- ISO 9613-2:2024
- Access
- Toolbar block
What it does
Calculates the attenuation due to atmospheric absorption over a propagation distance, ISO 9613-2:2024 clause 7.2, with the absorption coefficient computed from ISO 9613-1 for the air temperature, relative humidity and pressure you give.
Equation
with αatm in dB/km from ISO 9613-1 Formula (5), evaluated at the exact mid-band frequency Hz (63 Hz → 63.10 Hz, 8 kHz → 7943 Hz):
with T in kelvin, T0 = 293.15 K, T01 = 273.16 K and pr = 101.325 kPa (ISO 9613-1 Annex B).
ℹ️ Evaluating at the exact centre frequencies is what reproduces ISO 9613-2's Table 2; nominal frequencies do not. A relative humidity that is blank or 0 % gives no result (with the reason), rather than computing silently. Bands 63 Hz – 8 kHz (31.5 Hz is below ISO 9613-1's stated accuracy range). Timbral writes the result negative (an attenuation).
Inputs
| Input | Meaning | Unit | Example |
|---|---|---|---|
| T | air temperature | °C | 10 |
| hr | relative humidity (above 0, up to 100) | % | 70 |
| pa | atmospheric pressure (must be greater than 0) | kPa | 101.325 |
| d | propagation distance (must be greater than 0) | m | 500 |
Worked example
10 °C, 70 % relative humidity, 101.325 kPa (ISO 9613-2's reference conditions), d = 500 m:
| Band (Hz) | 63 | 125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 |
|---|---|---|---|---|---|---|---|---|
| αatm (dB/km) | 0.12 | 0.41 | 1.04 | 1.93 | 3.66 | 9.66 | 32.77 | 116.88 |
| Result (dB) | −0.06 | −0.21 | −0.52 | −0.96 | −1.83 | −4.83 | −16.39 | −58.44 |
The coefficients agree with ISO 9613-2 Table 2 (0.1, 0.4, 1.0, 1.9, 3.7, 9.7, 32.8, 117 dB/km at 10 °C and 70 %).
Source
ISO 9613-2:2024 — clause 7.2, Formula (9); ISO 9613-1:1993 — Formulae (3)–(6) and Annex B. Bands 63–8000 Hz.