- Formula
- ISO 389-7:2019 Table 1 reference threshold values (free-field or diffuse-field)
- Output
- dB SPL (re 20 µPa) — fills a row with the threshold of hearing
- Bands
- 1/3-octave centres 20 Hz – 16 kHz (fills whichever of these the sheet has)
- Standard / Source
- ISO 389-7:2019
- Access
- Curve fill
What it does
Fills the selected row with the reference threshold of hearing from ISO 389-7:2019 — the lowest sound pressure level an otologically normal young listener can just detect, band by band. Useful as an overlay to show whether a quiet or low-frequency component is likely to be audible at all. Pick Curves › Hearing › Hearing Threshold; the row is labelled “ISO 389-7 free-field threshold” and a yellow dropdown cell switches between the two listening conditions:
- Free-field (the default) — frontal incidence, pure tones.
- Diffuse-field — one-third-octave noise bands.
ℹ️ Available on every sheet kind. Any band of your sheet that the standard does not tabulate (e.g. below 20 Hz on the low-frequency sheet) is left blank. The values are tabulated, not calculated.
Worked example — octave sheet
| Band (Hz) | 31.5 | 63 | 125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 |
|---|---|---|---|---|---|---|---|---|---|
| Free-field (dB) | 59.5 | 37.5 | 22.1 | 11.4 | 4.4 | 2.4 | −1.3 | −5.4 | 12.6 |
| Diffuse-field (dB) | 59.5 | 37.5 | 22.1 | 11.4 | 3.8 | 0.8 | −1.5 | −3.8 | 6.8 |
(Below 315 Hz the two conditions are identical.)
Source
ISO 389-7:2019 — Acoustics: Reference zero for the calibration of audiometric equipment, Part 7: Reference threshold of hearing under free-field and diffuse-field listening conditions, Table 1. The 20 Hz value is 78.1 dB (the ISO 389-7 Amd 1:2016 correction of the 78.5 dB printed in ISO 226:2003).