Skip to content
ContentsFormula ReferenceUser guide
Formula Reference

ISO 226 Equal-Loudness Contour Fill

Formula
A_f = 4.47×10⁻³·(10^(0.025·L_N) − 1.15) + [0.4·10^((T_f + L_U)/10 − 9)]^α_f; L_p = (10/α_f)·log₁₀(A_f) − L_U + 94
Output
dB SPL (re 20 µPa) — fills a row with an equal-loudness contour
Bands
1/3-octave centres 20 Hz – 12.5 kHz (fills whichever of these the sheet has)
Standard / Source
ISO 226:2003
Access
Curve fill

What it does

Fills the selected row with an ISO 226:2003 equal-loudness contour — the sound pressure level of a pure tone, heard in a free field from the front, that sounds as loud as a 1 kHz tone of the chosen loudness level (in phon). Useful as a reference overlay when judging how audible a low- or high-frequency component is. Pick Curves › Hearing › Equal Loudness ISO 226; the row is labelled “ISO 226 40 phon” and the loudness level sits in a yellow dropdown cell (20, 30, 40, 50, 60, 70, 80 or 90 phon) — change it and the row refills.

ℹ️ Available on every sheet kind. The standard tabulates the 29 one-third-octave centres from 20 Hz to 12.5 kHz; any band of your sheet outside that range (e.g. below 20 Hz on the low-frequency sheet) is left blank. Default: 40 phon. Values are written to one decimal place.

Equation

For each tabulated band, with the ISO 226 Table 1 parameters α_f (exponent), L_U (magnitude) and T_f (threshold of hearing):

Af=4.47×10−3(100.025 LN−1.15)+[0.4×10(Tf+LU10−9)]αfA_f = 4.47\times10^{-3}\left(10^{0.025\,L_N} - 1.15\right) + \left[0.4\times10^{\left(\frac{T_f + L_U}{10} - 9\right)}\right]^{\alpha_f}
Lp=10αflog⁡10Af−LU+94L_p = \frac{10}{\alpha_f}\log_{10}A_f - L_U + 94

where L_N is the loudness level in phon.

Worked example — 40 phon (octave sheet)

Band (Hz)31.5631252505001000200040008000
Level (dB)88.273.160.650.443.140.039.236.651.8

(By definition a contour reads its own phon value at 1 kHz.)

⚠️ ISO 226 states the contours as valid for 20–90 phon up to 4 kHz and for a narrower loudness range above that. Timbral does not clamp or blank values outside that validity: they are the standard's fitted formula extrapolated.

Source

ISO 226:2003 — Acoustics: Normal equal-loudness-level contours, equations (1)/(2) and Table 1.