- Formula
- SPLext = SPLint + SRI + 10·log₁₀(S) − 20·log₁₀(r) − 14
- Output
- dB — two rows per band: Transfer Function (level difference) and Predicted external SPL
- Bands
- Follows the input spectrum
- Standard / Source
- General acoustics (no standard cited)
- Access
- Toolbar block
What it does
Predicts the outside sound pressure level a distance r from a building element, given the inside level, the element's sound reduction index, and its area — e.g. plant noise inside a room breaking out through a wall to a neighbour. Ribbon: Buildings → Inside → Outside.
The block has two result rows: the Transfer Function (the level change SRI + 10·log₁₀(S) − 20·log₁₀(r) − 14, which needs no source level) and, below it, the Predicted SPL outside. The internal SPL is optional — leave it blank and only the Transfer Function is filled.
Equation
The SRI is entered as a negative value (the element's attenuation). Bands with no SRI value are treated as 0 dB reduction; a positive SRI is treated as blocking the band entirely (Predicted SPL 0).
Inputs
| Input | Meaning | Unit | Example |
|---|---|---|---|
| SPLint | internal SPL (a spectrum row; optional) | dB | 91 |
| SRI | element sound reduction index (negative) | dB | −25 |
| S | element area | m² | 10 |
| r | distance to receiver | m | 5 |
Worked example
Taking the 125 Hz band — internal 91 dB, a 25 dB element (SRI = −25), S = 10 m², r = 5 m:
The Transfer Function row reads −25 + 10 − 13.98 − 14 = −43.0 dB at the same band. The same calculation runs in every band across the row.
Source
Standard outside-radiation relation. The −14 dB constant is not attributed to a specific published standard in the software.