Skip to content
ContentsFormula ReferenceUser guide
Formula Reference

G-Rating (Gym Acoustics)

Formula
lowest G-curve at or above the spectrum in every band (G10–G50, 1-unit resolution)
Output
G value (e.g. G35), or >G50 / <G10 outside the curve family
Bands
1/3-octave, 31.5 Hz – 4 kHz
Standard / Source
ProPG GAG 2023
Access
Toolbar block, Inline =function

What it does

Rates a one-third-octave spectrum against the G-curves of the ProPG Gym Acoustics Guidance — the rating scheme used to assess impact/structure-borne noise from gyms and similar activity spaces. It returns the lowest G-curve that encloses the spectrum, to 1-unit resolution.

Equation

The rating reports the lowest G-curve, to 1-unit resolution, that is at or above the spectrum in every band. >G50 means the spectrum breaks even the G50 contour in at least one band; <G10 means it lies below the G10 contour in every band (the family is undefined outside G10–G50). Blank or zero bands are skipped.

How to use it

  • From the ribbon — select the spectrum row(s) and choose Ratings → Sound Level → G-Rating (ProPG GAG 2023). This writes =GRATING(range, anchor) into each row's Rating column (click again to remove it) — no dialog, no inserted calc block. The item is disabled on 1/1-octave sheets.
  • As a function — =GRATING(range) (returns e.g. G35). It requires 1/3-octave input; octave-band data returns #NUM!.

Inputs

InputMeaningUnitExample
Spectrum1/3-octave levels 31.5 Hz–4 kHzdBlow-frequency-heavy spectrum

Worked example

A 1/3-octave spectrum peaking around 72–75 dB in the 63–125 Hz region rates above the top curve:

→ >G50

Source

ProPG Gym Acoustics Guidance (GAG) 2023, Appendix G — G-curve tables; band range 31.5 Hz–4 kHz.

Register interest

Tell us a little about you and we'll be in touch when Timbral is ready.