- Formula
- eVDV = 1.4 · RMS(weighted acceleration) · T^0.25
- Output
- m/s^1.75 (single value)
- Bands
- 1 Hz – 80 Hz (1/3-octave)
- Standard / Source
- ISO 2631-1
- Access
- Toolbar block
What it does
Estimates the Vibration Dose Value (eVDV) for human exposure to building vibration from a 1/3-octave acceleration spectrum (1–80 Hz), frequency-weighted for the chosen axis and integrated over a day or night exposure period. Used for assessing vibration nuisance/complaint risk against BS 6472-style dose criteria.
Equation
where RMS(a_w) = √Σ(aᵢ·Wᵢ)² is the band-by-band combination of the frequency-weighted acceleration spectrum (Wb weighting for the Z axis, Wd weighting for X/Y, per ISO 2631-1; bands left blank are skipped) and T is the exposure period in seconds (16 h = 57600 s for day, 8 h = 28800 s for night).
Inputs
| Input | Meaning | Unit | Example |
|---|---|---|---|
| Acceleration | 1/3-octave acceleration levels, 1–80 Hz (a spectrum row) | m/s² | see below |
| Axis | X, Y or Z (select) — sets Wd (X/Y) or Wb (Z) weighting | — | Z |
| Period | day (16 h) or night (8 h) (select) | — | day |
Worked example
Z-axis (Wb weighting), day period, with a single band filled: a = 0.01 m/s² at 8 Hz (Wb = 1.026 at 8 Hz):
RMS(a_w) = 0.01 × 1.026 = 0.01026 m/s²; T^0.25 = 57600^0.25 = 15.49
eVDV = 1.4 × 0.01026 × 15.49 → eVDV = 0.223 m/s^1.75 (0.187 m/s^1.75 for the night period)
Source
ISO 2631-1 — Wb/Wd frequency weighting curves for whole-body vibration; the 1.4×RMS×T^0.25 dose relation is the standard eVDV estimate used alongside BS 6472 assessment criteria.