- Formula
- ISO 11654 reference curve shifted to the class's lower αw bound: α = ref + (αw − 1.0)
- Output
- absorption coefficient α — fills a row with an absorption-class curve
- Bands
- 1/1-octave, 250 Hz – 4 kHz (octave sheets only)
- Standard / Source
- ISO 11654
- Access
- Curve fill
What it does
Fills the selected row with the ISO 11654 sound absorption class curve for class A, B, C, D or E — the standard reference curve shifted down to the lowest αw that still earns that class. A measured practical absorption spectrum that stays on or above the curve (within the standard's 0.10 allowance for unfavourable deviations) rates at least that class. Pick Curves › Absorption › Absorption Class A–E; the row is labelled e.g. “Absorption Class A”, described as “ISO 11654 class A curve (αw 0.90)”, and the class letter sits in a yellow dropdown cell so you can switch class.
ℹ️ Available on octave-band (1/1) sheets only. Only the five bands 250 Hz – 4 kHz are filled; the other bands are left blank.
Equation
The ISO 11654 reference curve is 0.80 / 1.00 / 1.00 / 1.00 / 0.90 at 250 / 500 / 1000 / 2000 / 4000 Hz. Each class curve shifts it by the class's lower αw bound minus 1.0:
| Class | A | B | C | D | E |
|---|---|---|---|---|---|
| αw bound | 0.90 | 0.80 | 0.60 | 0.30 | 0.15 |
Worked example
| Class | 250 Hz | 500 Hz | 1 kHz | 2 kHz | 4 kHz |
|---|---|---|---|---|---|
| A | 0.70 | 0.90 | 0.90 | 0.90 | 0.80 |
| B | 0.60 | 0.80 | 0.80 | 0.80 | 0.70 |
| C | 0.40 | 0.60 | 0.60 | 0.60 | 0.50 |
| D | 0.10 | 0.30 | 0.30 | 0.30 | 0.20 |
| E | −0.05 | 0.15 | 0.15 | 0.15 | 0.05 |
⚠️ In v0.9.0 the fill writes every value to one decimal place, so the class E row appears as −0.1 / 0.1 / 0.1 / 0.1 / 0.1 rather than the curve values above. Classes A–D are unaffected.
Source
ISO 11654 — Acoustics: Sound absorbers for use in buildings, rating of sound absorption (reference curve and sound absorption classes). See also the αw and Absorption Class (A–E) entries, which rate a spectrum against this curve.