Skip to content
ContentsFormula ReferenceUser guide
Formula Reference

Absorption Class Curve Fill (A–E)

Formula
ISO 11654 reference curve shifted to the class's lower αw bound: α = ref + (αw − 1.0)
Output
absorption coefficient α — fills a row with an absorption-class curve
Bands
1/1-octave, 250 Hz – 4 kHz (octave sheets only)
Standard / Source
ISO 11654
Access
Curve fill

What it does

Fills the selected row with the ISO 11654 sound absorption class curve for class A, B, C, D or E — the standard reference curve shifted down to the lowest αw that still earns that class. A measured practical absorption spectrum that stays on or above the curve (within the standard's 0.10 allowance for unfavourable deviations) rates at least that class. Pick Curves › Absorption › Absorption Class A–E; the row is labelled e.g. “Absorption Class A”, described as “ISO 11654 class A curve (αw 0.90)”, and the class letter sits in a yellow dropdown cell so you can switch class.

ℹ️ Available on octave-band (1/1) sheets only. Only the five bands 250 Hz – 4 kHz are filled; the other bands are left blank.

Equation

The ISO 11654 reference curve is 0.80 / 1.00 / 1.00 / 1.00 / 0.90 at 250 / 500 / 1000 / 2000 / 4000 Hz. Each class curve shifts it by the class's lower αw bound minus 1.0:

αclass(f)=αref(f)+(αw−1.0)\alpha_{class}(f) = \alpha_{ref}(f) + (\alpha_w - 1.0)
ClassABCDE
αw bound0.900.800.600.300.15

Worked example

Class250 Hz500 Hz1 kHz2 kHz4 kHz
A0.700.900.900.900.80
B0.600.800.800.800.70
C0.400.600.600.600.50
D0.100.300.300.300.20
E−0.050.150.150.150.05

⚠️ In v0.9.0 the fill writes every value to one decimal place, so the class E row appears as −0.1 / 0.1 / 0.1 / 0.1 / 0.1 rather than the curve values above. Classes A–D are unaffected.

Source

ISO 11654 — Acoustics: Sound absorbers for use in buildings, rating of sound absorption (reference curve and sound absorption classes). See also the αw and Absorption Class (A–E) entries, which rate a spectrum against this curve.

Register interest